1.
Arq. bras. oftalmol ; 86(3): 210-216, May 2023. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1439382

RESUMO

ABSTRACT Purpose: To evaluate primary intraocular lens implantation in the treatment of children's aphakia in the Brazilian public health system and compare the outcomes among different age groups. Methods: Children aged 0-12 years old with unilateral or bilateral congenital/developmental cataracts and underwent primary intraocular lens implantation were included. Results: A total of 108 eyes from 68 children were evaluated, and the children were divided into four age groups (<7 months [mo]; 7 mo-2 years old [y/o]; 2-5 y/o, and >5 y/o) were evaluated. Nineteen eyes (17.59%) presented visual axis opacification as a postoperative complication, which was more frequently observed in the <7 mo age group (37.93%). The difference was significant between the <7 mo and >5 y/o age groups (p=0.002). Visual axis opacification was divided into two categories: pupillary membrane and lens cell proliferation. Eight eyes presented pupillary membrane, whereas 14 showed lens cell proliferation. Out of eight eyes with pupillary membrane, seven occurred in the <7 mo age group. The difference between the <7 mo age group and the 2-5 y/o or >5 y/o age group was significant (p=0.01). Lens cell proliferation was more frequent in the <7 mo and 2-5 y/o age groups, but the difference was significant only between the < 7 mo age group and >5 y/o age group (p=0.040). Glaucoma and glaucoma suspect cases were not observed during the follow-up period. Conclusions: The main complication found in the study was visual axis opacification, which had a higher incidence in children operated on or before the age of 7 months.


RESUMO Objetivo: Avaliar o implante de lente intraocular primária para tratamento da afacia pediátrica no Sistema Único de Saúde (SUS) e comparar os resultados em diferentes faixas etárias. Métodos: Foram incluídas crianças com catarata congênita e do desenvolvimento unilateral ou bilateral de 0-12 anos de idade e submetidas a implante de lente intraocular primária. Resultados: Cento e oito olhos de 68 crianças divididas em quatro grupos de idade (<7m; 7m-2a; 2-5a e > 5a) foram avaliados. Dezenove olhos (17,59%) apresentaram opacificação do eixo visual como complicação pós-operatória. Essa complicação foi mais frequente na faixa etária <7 meses (37,93%). A diferença foi significativa entre os grupos de idade <7 meses e > 5 anos (p=0,002). A opacificação do eixo visual foi dividida em duas categorias: membrana pupilar e proliferação de células do cristalino. Oito olhos apresentaram membrana pupilar e 14 proliferação de células do cristalino. Dos oito olhos com membrana pupilar, sete ocorreram na faixa etária <7 meses. A diferença entre o grupo de idade <7 meses e os grupos de 2-5 anos e > 5 anos foi significativa (p=0,01). A proliferação de células do cristalino foi mais frequente nos grupos de idade <7 meses e 2-5 anos, mas significativa apenas quando comparados o grupo de idade <7 meses com o grupo> 5 anos de idade (p=0,040). Glaucoma e suspeitos de glaucoma não foram observados durante o acompanhamento. Conclusões: A principal complicação encontrada no estudo foi a opacificação do eixo visual. Sua incidência foi maior em crianças operadas antes dos 7 meses de idade.

2.
Arq. bras. oftalmol ; 85(3): 249-254, May-June 2022. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1383808

RESUMO

ABSTRACT Purpose: Creating models, in pediatric cataracts, to estimate kerotometry and axial length values at future ages, based on kerotometry and axial length measured at surgery, to estimate the intraocular lens power for emmetropia in future ages. Methods: Eyes with bilateral cataract and kerotometry and axial length measured at surgery and at least one postoperative examination with kerotometry and axial length measurements, were considered for this study. The models to estimate future kerotometry and axial length values were created considering (1) kerotometry and axial length measured at surgery, (2) the average slope of kerotometry and axial length logarithmic regression created for every single eye and (3) age at surgery. The intraocular lens for future ages can be estimated using these values in third generation formulas. The estimation errors for kerotometry, axial length and intraocular lens were also calculated. Results: A total of 57 eyes from 29 patients met the inclusion criteria. The average age at the surgery and follow-up was 36.96 ± 32.04 months and 2.39 ± 1.46 years, respectively. The average slope of logarithmic regression created for every single eye were -3.286 for kerotometry and +3.189 for axial length. The average absolute estimation errors for kerotometry and axial length were respectively: 0.61 ± 0.54 D and 0.49 ± 0.55 mm, and for intraocular lens using SRK-T, Hoffer-Q and Holladay I formulas were: 2 . 04 ± 1 . 73 D , 2 . 49 ± 2 . 10 D and 2 . 26 ± 1 . 87 D, respectively. Conclusions: The presented models could be used to estimate the intraocular lens power for emmetropia at future ages to guide the choice of the intraocular lens power to be implanted in pediatric cataract.


RESUMO Objetivo: Criar modelos, em catarata pediátrica, para estimar valores futuros de ceratometria e comprimento axial, com base na ceratometria e no comprimento axial medidos na cirurgia, para previsão do poder da lente intraocular para emetropia em idades futuras. Métodos: Olhos com catarata bilateral, ceratometria e comprimento axial medidos na cirurgia e pelo menos um exame pós-operatório com medidas de ceratometria e comprimento axial foram considerados para este estudo. Os modelos para estimar futuras ceratometrias e comprimentos axiais foram criados considerando (1) ceratometria e comprimento axial medidos na cirurgia, (2) a inclinação média da regressão logarítmica da ceratometria e comprimento axial criada para cada olho e (3) a idade na cirurgia. A lente intraocular para emetropia em idades futuras pode ser estimada usando esses valores em fórmulas de terceira geração. Os erros de estimativa da ceratometria, comprimento axial e poder da lente intraocular, usando os modelos, também foram calculados. Resultados: 57 olhos de 29 pacientes preencheram os critérios de inclusão. A idade média na cirurgia e acompanhamento foram de 36,96 ± 32,04 meses e 2,39 ± 1,46 anos, respectivamente. A inclinação média da regressão logarítmica criada para cada olho foi de -3.286 para ceratometria e + 3.189 para o comprimento axial. Os erros médios de estimativa absoluta para ceratometria e comprimento axial foram respectivamente: 0,61 ± 0,54 D e 0,49 ± 0,55 mm, e para o poder da lente intraocular usando as fórmulas SRK-T, Hoffer-Q e Holladay I foram: 2,04 ± 1,73 D, 2,49 ± 2,10 D e 2,26 ± 1,87 D, respectivamente. Conclusões: Os modelos apresentados podem ser utilizados para estimar o poder da lente intraocular que levaria a emetropia em idades futuras e orientar a escolha do poder da lente intraocular a ser implantada na catarata pediátrica.

3.
Arq. bras. oftalmol ; 82(4): 289-294, July-Aug. 2019. tab
Artigo em Inglês | LILACS | ID: biblio-1019413

RESUMO

ABSTRACT Purpose: To evaluate whether training medical residents with the Eyesi® cataract surgery simulator reduces the occurrence of intraoperative complications. Methods: This was a retrospective study in which the first 10 phacoemulsification surgeries performed by two groups of second-year ophthalmology residents were evaluated, during 2014 and 2015. The first Group consisted of seven residents from 2014 who had not had previous training with the simulator. The second Group was formed of seven residents in 2015, who had completed the C-level (intermediate) training with the simulator before beginning surgery on patients. We then compared these two groups regarding the frequency of occurrence of the four main intraoperative surgical complications: posterior capsule rupture, aphakia, and nucleus fragment dislocation into the vitreous, and extracapsular conversion. Results: A total of 140 surgeries were performed, 70 by Group 1 and 70 by Group 2. The total number of complications was 19 (27.14%) in Group 1 and nine (12.86%) in Group 2, and this reduction was significant (p=0.031). Fourteen (20%) surgeries in Group 1 and seven (10%) in Group 2 had complications. The complications were 13 posterior capsule ruptures (18.57%) in Group 1 and seven (10%) in Group 2; three eyes had nucleus fragment dislocations (4.29%) in Group 1, but only one (1.43%) in Group 2; two extracapsular conversions (2.86%) occurred in Group 1 and one (1.43%) in Group 2; and there was one aphakia (1.43%) in Group 1. Conclusions: The training with the Eyesi® cataract surgery simulator significantly reduced the total number of intraoperative complications in the first 10 phacoemulsification cataract surgeries performed by ophthalmology residents.


RESUMO Objetivo: Avaliar se o treinamento de residentes médicos com o simulador de cirurgia de catarata Eyesi® reduz a ocorrência de complicações intraoperatórias. Métodos: Estudo retrospectivo em que foram avaliadas as primeiras 10 cirurgias de facoemulsificação realizadas por dois grupos de residentes de Oftalmologia do segundo ano, no período de 2014 a 2015. O primeiro Grupo foi formado por sete residentes de 2014 que não tiveram treinamento prévio no simulador. O segundo Grupo foi formado por sete residentes de 2015, que completaram o treinamento até o nível C (intermediário) no simulador antes de iniciar a cirurgia em pacientes. Em seguida, comparamos esses dois grupos em relação à frequência de ocorrência das quatro principais complicações cirúrgicas intraoperatórias: ruptura da cápsula posterior, afacia e deslocamento de fragmentos de núcleo para o vítreo e conversão para extracapsular. Resultados: Foram realizadas 140 cirurgias, sendo 70 pelo Grupo 1 e 70 pelo Grupo 2. O número total de complicações foi de 19 (27,14%) no Grupo 1 e nove (12,86%) no Grupo 2, e esta redução foi significativa (p=0,031). Quatorze (20%) cirurgias no Grupo 1 e sete (10%) no Grupo 2 tiveram complicações. As complicações foram 13 rupturas de cápsula posterior (18,57%) no Grupo 1 e sete (10%) no Grupo 2, três olhos com luxação de fragmento de núcleo para o vítreo (4,29%) no Grupo 1 e um (1,43%) no Grupo 2, duas conversões extracapsulares (2,86%) no Grupo 1 e uma (1,43%) no Grupo 2 e uma afacia (1,43%) no Grupo 1. Conclusões: O treinamento com o simulador de cirurgia de catarata Eyesi® reduziu significativamente o número total de complicações intraoperatórias nas primeiras 10 cirurgias de catarata por facoemulsificação realizadas por residentes de oftalmologia.


Assuntos
Humanos , Facoemulsificação/educação , Facoemulsificação/efeitos adversos , Treinamento por Simulação/métodos , Complicações Intraoperatórias/prevenção & controle , Corpo Clínico Hospitalar/educação , Oftalmologia/educação , Reprodutibilidade dos Testes , Estudos Retrospectivos , Resultado do Tratamento , Internato e Residência/métodos
4.
Arq. bras. oftalmol ; 82(1): 62-64, Jan.-Feb. 2019. graf
Artigo em Inglês | LILACS | ID: biblio-973864

RESUMO

ABSTRACT We report the case of a 4-year-old boy with Marfan syndrome whose parents reported he had had low visual acuity since birth. On examination, there was microspherophakia and a small subluxation of the lens. The objective refraction was -23.75 - 2.75 x 70 in the right eye and -25.50 -3.50 x 90 in the left eye. Since the microspherophakia and the high myopia severely affected the boy's quality of life, clear lens extraction, anterior vitrectomy, posterior surgical capsulotomy via the pars plana, and intraocular lens implantation were performed. Two years postoperatively, the patient had centered intraocular lenses and a corrected visual acuity of 20/30 in both eyes. The child was satisfied with his vision and was able to study and perform daily activities without visual limitations.


RESUMO Reportamos o caso de um menino de 4 anos de idade com Síndrome de Marfan, cujos pais referiam que o mesmo apresentava baixa acuidade visual desde o nascimento. Ao exame oftalmológico, observou-se microesferofacia e discreta subluxação do cristalino bilateralmente. A refração estática era -23.75 - 2.75 x 70 no olho direito e -25.50 -3.50 x 90 no olho es querdo. Como a microesferofacia e a alta miopia traziam sérios prejuízos à qualidade de vida do paciente, foi submetido à facoemulsificação de cristalino transparente, vitrectomia anterior, capsulotomia posterior via pars plana e implante de lente intrao cular. Em seguimento pós-operatório de dois anos, mantinha lentes intraoculares centradas, eixo visual livre, acuidade visual corrigida de 20/30 em ambos os olhos. Paciente satisfeito com a visão podendo estudar e exercer todas as atividades do dia a dia sem limitações visuais.


Assuntos
Humanos , Masculino , Pré-Escolar , Ectopia do Cristalino/cirurgia , Glaucoma/cirurgia , Iris/anormalidades , Doenças da Córnea/cirurgia , Implante de Lente Intraocular/métodos , Cristalino/cirurgia , Síndrome de Marfan/cirurgia , Acuidade Visual , Iris/cirurgia , Subluxação do Cristalino/cirurgia , Resultado do Tratamento